Reduction of Active and Reactive Power Losses on Transmission Lines Using Static Synchronous Series Compensator (SSSC):-Uzor, John I.

JOHN IHEJIONUEME | 121 pages (24696 words) | Theses

ABSTRACT

This thesis discusses a comprehensive study on reduction of power (active and reactive) losses in transmission lines using a second generation FACTS device, Static Synchronous Series Compensator (SSSC). Modem restructured power systems sometimes operate with heavily loaded lines resulting in power losses and higher voltage deviations, which may lead to mal-operation of power system and eventual collapse ofthe system. This is mainly due to continuous and uncertain growth in demand for electrical power. The research work presents a methodology to solve the problem of power losses in the Nigerian 28 - bus power system by incorporating Static Synchronous Series Compensator in the network using Newton-Rahson power flow algorithm. Simulation of power flow solution without and with the FACTS device was done using a Matlab software. The results showed that the maximum power (active and reactive) loss in the system without SSSC occurred in the transmission line connecting bus 17 (Jebba) to bus 23(Shiroro) and 19.32% loss reduction was noticed on the line after the incorporation ofthe SSSC FACTS device giving a power saving of 80.68%. The total system active and reactive power losses before the application of SSSC was 205.183MW and 1594.683MVAR respectively. However, when the FACTS device was applied at the weak buses the total system active and reactive power losses reduced to 144.571MW and 1136.863MVAR respectively giving a percentage loss reduction in active and reactive power of 29.54% and 28.71% respectively resulting in a power saving of 70.46% and 71.29%. Hence, more power was available in the network when compared to the base case due to the installation of SSSC. Also an improvement in the voltage magnitude at the weak buses and other buses were noticed as they were all maintained at 1.0 PU.

Overall Rating

0.0

5 Star
(0)
4 Star
(0)
3 Star
(0)
2 Star
(0)
1 Star
(0)
APA

JOHN, I (2023). Reduction of Active and Reactive Power Losses on Transmission Lines Using Static Synchronous Series Compensator (SSSC):-Uzor, John I. . Mouau.afribary.org: Retrieved Dec 24, 2024, from https://repository.mouau.edu.ng/work/view/reduction-of-active-and-reactive-power-losses-on-transmission-lines-using-static-synchronous-series-compensator-sssc-uzor-john-i-7-2

MLA 8th

IHEJIONUEME, JOHN. "Reduction of Active and Reactive Power Losses on Transmission Lines Using Static Synchronous Series Compensator (SSSC):-Uzor, John I. " Mouau.afribary.org. Mouau.afribary.org, 22 Nov. 2023, https://repository.mouau.edu.ng/work/view/reduction-of-active-and-reactive-power-losses-on-transmission-lines-using-static-synchronous-series-compensator-sssc-uzor-john-i-7-2. Accessed 24 Dec. 2024.

MLA7

IHEJIONUEME, JOHN. "Reduction of Active and Reactive Power Losses on Transmission Lines Using Static Synchronous Series Compensator (SSSC):-Uzor, John I. ". Mouau.afribary.org, Mouau.afribary.org, 22 Nov. 2023. Web. 24 Dec. 2024. < https://repository.mouau.edu.ng/work/view/reduction-of-active-and-reactive-power-losses-on-transmission-lines-using-static-synchronous-series-compensator-sssc-uzor-john-i-7-2 >.

Chicago

IHEJIONUEME, JOHN. "Reduction of Active and Reactive Power Losses on Transmission Lines Using Static Synchronous Series Compensator (SSSC):-Uzor, John I. " Mouau.afribary.org (2023). Accessed 24 Dec. 2024. https://repository.mouau.edu.ng/work/view/reduction-of-active-and-reactive-power-losses-on-transmission-lines-using-static-synchronous-series-compensator-sssc-uzor-john-i-7-2

Related Works
Please wait...